MSDS BIS CALB Grade A 3.2V 163Ah LifePo4 Battery Cell Lithium Ion For E-Scooter

ItemParameterRemarkL173F163ASpot Welding typeL173F163BScrew typeRated Voltage3.2VRated Capacity163AhCharge modeCC/CVCharge cut off voltage3.65VDischarge Cut off voltage2.5VStandard charge0.2C (32.6A)(

Item
Parameter
Remark
L173F163A
Spot Welding type

L173F163B
Screw type

Rated Voltage
3.2V

Rated Capacity
163Ah

Charge mode
CC/CV

Charge cut off voltage
3.65V

Discharge Cut off voltage
2.5V

Standard charge
0.2C (32.6A)
(0℃
Quick charge
0.5C (81.5A)
(5℃
Max. charge
1C (163A)
(15℃
Standard Discharge
0.2C (32.6A)

Max. discharge current
1C (163A)

Max. Pulse Discharge current (long time)
326A
Maximum duration: 3min
Max. Pulse Discharge current (short time)
489A
When battery temperature is below 50℃, the maximum discharge can last 30s
Inner resistance
≤0.5mΩ at AC 1KHz

Size
L173F163A (spot welding type)
36.4±0.15x174.4±0.15x 217.3±0.4 /TH:220.0±0.3mm
(TxWxH/TH)
L173F163B (screw type) (TxWxH/TH)
36.36±0.15x174.4±0.15x 217.3±0.4 /TH:230.5±0.6mm
Approx. Weight
3.25KGS

Cycle life
≥4000 times
at 0.2C & 25℃
Operation Temperature
Charge Temperature
0~55℃

Discharge Temperature
-20~60℃

Grade A quality,available for power and energy storage.

Welding screw type

This CALB is aluminum shell,with UN38.3,MSDS,CE,RoHS certificate.

 

This CALB is aluminum shell,with UN38.3,MSDS,CE,RoHS certificate.

 

Busbars dimensions.

1.This item is 163Ah item,the QR code is intact,Grade A,Brand new.

2.The price come with Bus bars and Bolts.

3.The busbars size:78x 20 x 1.6mm(cooper plated with nickel) Screw size:M6

4.We will test all the battery Voltage and Internal resistance Voltage:The deviation less than 0.01V Resistance:The deviation less than 0.1mΩ

CALB 163AH busbar size  .jpg

Why Lithium-Iron Phosphate(LiFePO4 or LFP)?


Lithium-iron-phosphate (LiFePO4 or LFP) is the safest of the mainstream li-ion battery types.Lithium batteries offer many benefits over other battery chemistries. They are a safe and reliable battery solution, with no fear of thermal runaway and/or catastrophic meltdown, which is a significant possibility from other lithium battery types. These batteries offer extremely long cycle life,with some manufacturers even warranting batteries for up to 10,000 cycles. With high discharge and recharge rates upwards of C/2 continuous and a round-trip efficiency of up to 98%, it's no wonder these batteries are gaining traction within the industry.Lithium Iron Phosphate (LiFePO4) is a perfect energy storage solution.
 
What is the Battery Management System (BMS) and the way will it work ?

BMS Protection options :
● Low Voltage Protection Switch – mechanically disconnects at ten.0V
● Over Voltage Protection Switch – mechanically disconnects at fourteen.8V
● Short Circuit Protection Switch – mechanically and safely disconnects battery
● Reverse Polarity Protection Switch – mechanically and safely disconnects battery
● Over temperature – mechanically shut-down battery till traditional temperature recovery
Balancing options :
● Internal cell reconciliation – mechanically balances BLS® cells throughout battery operation. reconciliation
algorithmic rule has been developed to confirm excellent balance between cells throughout battery life.
● Charge reconciliation – for BLS® connected in parallel and/or nonparallel, the BMS can balance every BLS® severally, so as to produce a perpetually balanced battery system.

 
I Must Use The Battery Management System (BMS)?

Important facts:An LFP cell will fail if the voltage over the cell falls to less than 2.5V (note: recovery by charging with a low current, less than 0.1C, is sometimes possible).An LFP cell will fail if the voltage over the cell increases to more than 4.2V. Lead-acid batteries will eventually also be damaged when discharged too deeply or overcharged, but not immediately. A lead-acid battery will recover from total discharge even after it has been left in a discharged state during days or weeks (depending on battery type and brand).

The cells of an LFP battery do not auto-balance at the end of the charge cycle. The cells in a battery are not 100% identical.Therefore, when cycled, some cells will be fully charged or discharged earlier than others. The differences will increase if the cells are not balanced/equalized from time to time. In a lead-acid battery a small current will continue to flow even after one or more cells are fully charged (the main effect of this current is decomposition of water into hydrogen and oxygen). This current helps to fully charge other cells that are lagging behind, thus equalizing the charge state of all cells. The current through an LFP cell, however, when fully charged, is nearly zero, and lagging cells will therefore not be fully charged. Over time the differences between cells may become so extreme that, even though the overall battery voltage is within limits, some cells will fail due to over- or under-voltage. Cell balancing is therefore highly recommended.
In Addition To Cell Balancing, A BMS Will:
* Prevent cell under voltage by timely disconnecting the load.
* Prevent cell overvoltage by reducing charge current or stopping the charging process.
* Shut down the system in case of over temperature.
* A BMS is, therefore, indispensable to prevent damage to large Li-ion battery banks.

Are Lithium batteries safe?

The Lithium Iron Phosphate (LiFePO4) batteries are the safest type of Lithium batteries as they will not overheat, and even if punctured they will not catch on fire. The cathode material in LiFePO4 batteries is not hazardous, and so poses no negative health hazards or environmental hazards. Due to the oxygen being bonded tightly to the molecule, there is no danger of the battery erupting into flames like there is with Lithium-Ion. The chemistry is so stable that LiFePO4 batteries will accept a charge from a Lead- Acid configured charger.

What is the life expectancy of a Lithium battery?

The typical estimated life of the Lithium Iron Phosphate (LiFePO4) battery is 5-15 years, or 2000 to 8000 charge cycles. One charge cycle is a period of use from fully charged, to fully discharged, and fully recharged again.
If I want to solar charge LiFePO4/Lithium Ion battery, which already has PCB, would a normal SLA controller work fine?
For LiFePO4 / Lithium Ion battery, we always recommend to use LiFePO4/Lithium Ion solar controller. Especially if you are using the battery as UPS (back up power supply). The Lead Acid solar controller will constantly provide pulse current to the battery, in the long run, it might damage the PCB. So the PCB won't be able to protect the battery when it should be.
The LiFePO4 / Lithium Ion solar controller won't provide constant current when the battery is fully charged. So it is much safer and reliable.

 
I have a lead acid charger with high charging current; can I use it instead to charge LiFePO4 batteries?

Lead acid batteries charge at 2.30V to 2.45V per cell whereas LiFePO4 batteries require 3.65V per cell. Your battery would
potentially be undercharged, so you will not get use of the full capacity of the LiFePO4 battery, nor will balancing be triggered in the LiFePO4 battery pack, both of which are not desired. Furthermore, the floating charge of the lead acid charger is not expected by the battery and can cause problems. We recommend purchasing the battery with the bundled charger.